Time Delay Relay

Home ProductTime Delay Relay

12v Adjustable Timer

DC12V DC24V AC220V AC380V Time delay relay off delay adjustable 10h Applications Used in control cabinets, cabinets and other electrical control circuit, according to the scheduled time automatically switch on or off the circuit. Features: Built-in microcontrollers, 0.1s~100h wide delay range,...

Product Description

DC12V DC24V AC220V AC380V Time delay relay off delay adjustable timer 10h

Applications

Used in control cabinets, cabinets and other electrical control circuit, according to the scheduled time automatically switch on or off the circuit.

Features:

Built-in microcontrollers, 0.1s~100h wide delay range, repeat accuracy≤0.2%.Knob setting, LED indicator shows working status. Variety of optional rated voltage. DIN rail mounting.

Model Description

图片61

Model Selection Table

Model

Function

Rated supply voltage

Contact

Delay range

ZHRT2-E

Signal on, relay on;

signal off,delay of relay off

DC12V

DC24V

AC110V

AC220V

AC380V

AC/DC24V~240V

1:1 C/O

2:2 C/O

2T:1C/O+1 instant C/O

3:3 C/0

0.1s~100h

Technical Parameters

Rated control supply voltage

DC12V、DC24V AC110V、AC220V、AC380V AC/DV 24V~240V 50/60Hz

Rated power consumption

AC:≤1.5VA DC: ≤1W

Delay range

0.1s~100h multi-range adjustment

Setting accuracy

≤5%

Repeat accuracy

≤0.2%

Repeat power-on interval

≥200ms

Electrical Life

105

Mechanical life

106

Altitude

≤2000m

Contact configuration capacity(A)

1C/O 2C/O 16A,1C/O+1 instant C/O,3C/O 8A

IP Class

IP20

Class of pollution

Use category

AC-15

Contact capacity

Ue/le AC240V/1.5A,AC380V/0.95A

Output type

1C/O;2C/O;1C/O+1 instant C/O

Standard Guide

(width)35mm(IEC/EN60715)

Function diagram

图片62

Wiring Diagram

图片63

Dimensions(mm)

图片64

12v relay minimum voltage,12v to 240v relay,icm time delay relay,off timer relay and interval timer relay,please kindly contact us when you need more different function relay.

The Timer delay relay almost functions as follows:

A. On Delay Power On:When the input voltage U is applied, timing delay t begins. Relay contacts R change state after time delay is complete. Contacts R return to their shelf state when input voltage U is removed. Trigger switch is not used in this function.

B. Repeat Cycle Starting Off:When input voltage U is applied, time delay t begins. When time delay t is complete, relay contacts R change state for time delay t. This cycle will repeat until input voltage U is removed. Trigger switch is not used in this function.

C. Interval Power On:When input voltage U is applied, relay contacts R change state immediately and timing cycle begins. When time delay is complete, contacts return to shelf state. When input voltage U is removed, contacts will also return to their shelf state. Trigger switch is not used in this function.

D. Off Delay S Break:Input voltage U must be applied continuously. When trigger switch S is closed, relay contacts R change state. When trigger switch S is opened, delay t begins. When delay t is complete, contacts R return to their shelf state. If trigger switch S is closed before time delay t is complete, then time is reset. When trigger switch S is opened, the delay begins again, and relay contacts R remain in their energized state. If input voltage U is removed, relay contacts R return to their shelf state.

E. Retriggerable One Shot:Upon application of input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay contacts R transfer and the preset time t begins. At the end of the preset time t, the relay contacts R return to their normal condition unless the trigger switch S is opened and closed prior to time out t (before preset time elapses). Continuous cycling of the trigger switch S at a rate faster than the preset time will cause the relay contacts R to remain closed. If input voltage U is removed, relay contacts R return to their shelf state

F. Repeat Cycle Starting On:When input voltage U is applied, relay contacts R change state immediately and time delay t begins. When time delay t is complete, contacts return to their shelf state for time delay t. This cycle will repeat until input voltage U is removed. Trigger switch is not used in this function.

G. Pulse Generator:Upon application of input voltage U, a single output pulse of 0.5 seconds is delivered to relay after time delay t. Power must be removed and reapplied to repeat pulse. Trigger switch is not used in this function.

H. One Shot:Upon application of input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay contacts R transfer and the preset time t begins. During time-out, the trigger signal S is ignored. The relay resets by applying the trigger switch S when the relay is not energized.

I. On / Off Delay S Make / Break:Input voltage U must be applied continuously. When trigger switch S is closed, time delay t begins. When time delay t is complete, relay contacts R change state and remain transferred until trigger switch S is opened. If input voltage U is removed, relay contacts R return to their shelf state.

J. Memory Latch S Make:Input voltage U must be applied continuously. Output changes state with every trigger switch S closure. If input voltage U is removed, relay contacts R return to their shelf state.

Any more your function or questions, please contact us.