Single Phase Solid State Relay

Home ProductSingle Phase Solid State Relay

Solid State DC Relay 40 Amp

10A 25A 40A 50A 60A 80A 90A 100A 120A SSR DA/DD/AA Single phase/Three Phase Solid State Relay STEP 1: Choose a correct type for current For Resistive load: Current of SSR =2 x working current of load For Inductive load:Current of SSR =6 x working current of load For Capacitive load: Current of...

Product Description

Model

SSR-1 DD220D10/DD220D25/DD220D40

Control Voltage

3-32VDC

Min Control Current

5mA

Max Control Current

20mA

Load Voltage

5-220VDC

Load Current

10A/25A/40A

Insulation Resistance

1000M Ohm/ 500VDC

Off Leakage Current

<=5mA

On Voltage

<=1.6V

On-off Time

<=10ms

Ambient Temperature

-30~+70 ℃

Mounting Method

Screw fixed

10A 25A 40A 50A 60A 80A 90A 100A 120A SSR DA/DD/AA Single phase/Three Phase Solid State Relay

STEP 1: Choose a correct type for current

For Resistive load: Current of SSR =2 x working current of load

For Inductive load:Current of SSR =6 x working current of load

For Capacitive load: Current of SSR =10 x working current of load

STEP 2: Choose a suitable heat sink.

When SSR working, it will give out a lot of heat, so in order to extend the life of your SSR, please install a heat sink , also if the current is over 60A,the cooling fan also required.

And don't forget apply heat-conductive silicon greasebetween SSR and heat sink.

Attention: 1. Use fast fuse to protect SSR from load short circuit.

2. The temperature of heatsink atuse must below 80°C.

3. It is better to use varistor for inductive load..

1 2

3

45678910

Solid state relays is a kind of electronic switch that without mechanical contacts, adopting photoelectric device and transformer to electric isolate or signal couple the control circuit (input circuit) and load circuit (output circuit), drive solid power device to make and break or switch the load circuit. Although there are various solid state relays of different specifications in the market, their working principle is similar, and mainly made up of input (control) circuit, drive circuit and output (load) circuit.

The input circuit of solid state relays is used to input control signal and work as the triggering signal source. Generally, the input circuit of solid state relays is DC input (like resistant input, the input current will have a linear variation when voltage changes), but some are AC input.


Send Inquiry

Copyright © 2023 Yueqing Aukeman Electric Co.,Ltd XML | Sitemaps