Home ProductSingle Phase Solid State Relay
Model |
SSR-1 DD220D80 |
Control Voltage |
3-32VDC |
Min Control Current |
5mA |
Max Control Current |
20mA |
Load Voltage |
5-220VDC |
Load Current |
80A |
Insulation Resistance |
1000M Ohm/ 500VDC |
Off Leakage Current |
<=5mA |
On Voltage |
<=1.6V |
On-off Time |
<=10ms |
Ambient Temperature |
-30~+70 ℃ |
Mounting Method |
Screw fixed |
Notice for operation of solid state relays
1.Input control signal:
The input control frequency of AC solid state relay should not exceed 10Hz; the period for DC solid state relay to control signal should more than 5 times of the summation of making time and breaking time of relay. When the ambient is too high, please decrease the control current appropriately, and when the ambient is too low, please increase the control current appropriately. Try to shorten the input line and adopt twin line or twisted pair wire to reduce the radio frequency interference. When there are contactor or automatic switch exists, you can parallel connect capacitance or RC circuit that series connected with resistance and capacitance on the input terminal, or series connected with electromagnetic filter and filter circuit that made by LC to prevent from error connection caused by electromagnet interference.
2.Output protecting circuit:
In the actual application, non-resistance load is used often, please add corresponding protecting circuit, such as quick-acting fuse, transient suppressing circuit (absorption circuit), voltage dependent resistor MOV and discharging appliance, etc., see diagram B and C.
Some products listed in this manual already contain absorption circuit (such as the output specification of OL or 1L).