Phase Sequence Voltage Relay

Home ProductPhase Sequence Voltage Relay

Unbalanced Voltage Relay AC220V

1. "●"Function is available, "-"Function is not available. "○"Function can be customized.
2. In three-phase four-wire circuit, relay without phase sequence protection could achieve single-phase or two-phase protection.
3. Choose either PTC protection or load protection.
4. Load protection: L1/L2/L3(P-P).

Product Description

Model Description

Model Selection Table

Model

Over-voltage

Under-voltage

Unbalance

Phase sequence

Phase failure

Reset

Test

PTC Protection

Load protection


Setting range

Delay range

Setting range

Delay range

Setting range

Delay range

ZHRV1-14

1.15

2s

0.85

2s

8%

2s

Note:

1. "●"Function is available, "-"Function is not available. "○"Function can be customized.

2. In three-phase four-wire circuit, relay without phase sequence protection could achieve single-phase or two-phase protection.

3. Choose either PTC protection or load protection.

4. Load protection: L1/L2/L3(P-P).

Technical Parameters

Rated supply voltage

AC220V、AC230、AC240V、AC380V、AC400V、AC415V

Rated supply frequency

50Hz/60Hz

Over-voltage threshold range

(1.05~1030)×Ue

Under-voltage thershold range

(0.70~0.95) ×Ue

Unbalance threshold range

5%~15%

Action delay range

0.1s~10s

Phase failure and phase sequence

≤1s

Voltage measurement error

≤1%( Entire setting range)

Delay error

±10%+0.1s

Knob setting accuracy

±1%/Scale value

Rated insulation voltage

415V

Contact configuration capacity(A)

10A

IP Class

IP20

Class of pollution

Electrical Life

105

Mechanical life

106

Altitube

≤2000m

Allowable relative humidity

≤50%(40℃)( No condensation)

Use category

AC-15

Short circuit protector type

RT36-00 5A

Contact capacity

Ue/le:240V/1.5A,415V/0.95A

Output type

1C/O

DIN rail Standard

(width)35mm(IEC/EN60715)

Function diagram

image002

Wiring Diagram

image003

Dimensions(mm)

image005

Ordering instructions

Model significance:

ZHRV1-04/A380 voltage relays, rated voltage AC 380V with phase failure, phase sequence, over-voltage protection. Adjustable over-voltage range(1.05-1.3)Ue, under-voltage range(0.7-0.95)Ue, unbalance protection range(5%-15%)Ue, action delay time 0.1s to 10s.

Advice:

If you want to get under voltage protection relays, 230V relays, overvoltage and undervoltage protection relays,voltage control relays,undervoltage relays and so on ,please choose this one to help you save time.


Send Inquiry

Copyright © 2023 Yueqing Aukeman Electric Co.,Ltd XML | Sitemaps